The right air conditioner size depends mainly on the square footage you’re cooling. A unit that’s too small runs constantly and never catches up. One that’s too big is just as bad: it cools the room before it can pull out the humidity, so the space feels cold and clammy, and it wastes energy cycling on and off. ENERGY STAR’s advice is blunt: bigger is not better.
Step 1: Measure the room
Multiply the room’s length by its width in feet. Convert inches to fractions of a foot (6 inches = 0.5 ft). A 12 ft 6 in × 14 ft room is 12.5 × 14 = 175 sq ft. For an L-shaped room, split it into rectangles and add them together.
Step 2: Find your BTU size
This chart follows ENERGY STAR’s sizing guidance for room air conditioners and assumes an 8-foot ceiling.
| Area to cool (sq ft) | Capacity needed (BTU/hr) |
|---|---|
| 100 – 150 | 5,000 |
| 150 – 250 | 6,000 |
| 250 – 300 | 7,000 |
| 300 – 350 | 8,000 |
| 350 – 400 | 9,000 |
| 400 – 450 | 10,000 |
| 450 – 550 | 12,000 |
| 550 – 700 | 14,000 |
| 700 – 1,000 | 18,000 |
| 1,000 – 1,200 | 21,000 |
| 1,200 – 1,400 | 23,000 |
| 1,400 – 1,500 | 24,000 |
| 1,500 – 2,000 | 30,000 |
| 2,000 – 2,500 | 34,000 |
Step 3: Adjust for your room
- Very sunny room: add 10%.
- Heavily shaded room: subtract 10%.
- More than two people regularly in the room: add 600 BTU for each additional person.
- Kitchen: add 4,000 BTU for the heat from cooking.
- Ceilings higher than 8 feet: size up, since there’s more air to cool.
Example: a 350 sq ft sunny living room used by four people. Start at 8,000 BTU, add 10% for sun (8,800), then add 1,200 for two extra people, for about 10,000 BTU.
What about central air?
Central air conditioners and heat pumps are sized in tons (1 ton = 12,000 BTU/hr). Rules of thumb like “one ton per 500 square feet” are often wrong, because insulation, windows, air leaks, ductwork and climate matter as much as floor area.
The right way is a Manual J load calculation, the industry standard from ACCA. A good HVAC contractor will do one before quoting a new system. If a contractor just matches the size of your old unit or guesses from square footage, ask for a Manual J. Many older systems were oversized to begin with.
Other things to check before you buy
- Electrical: larger window units may need a dedicated circuit, and some need a 230/240-volt outlet. See do air conditioners need a dedicated circuit?
- Efficiency: look for a high CEER rating and the ENERGY STAR label. Variable-speed (inverter) units run quieter and hold temperature more evenly.
- Window fit: measure the window opening before you shop, and use the included insulation panels. A poorly sealed unit leaks a lot of cool air.
- Other options: for several rooms, a ductless mini-split is often more efficient than multiple window units. See types of air conditioners.
Frequently asked questions
Is it OK to buy a slightly bigger unit just in case?
Not by much. An oversized unit short-cycles, removes less humidity and costs more to run. Stay within the chart, adjusted for your room.
Do portable air conditioners follow the same chart?
Roughly, but portable units are usually less efficient than window units of the same BTU rating, so many people size them up a step. Check the manufacturer’s recommended room size.
Sources: ENERGY STAR room air conditioner sizing guidance; ACCA Manual J.